Input
Features
| ¡@ | > | Input range : 90-264VAC |
| ¡@ | > | Frequency : 47 - 63Hz |
| ¡@ | > | Power factor : >0.9 |
| ¡@ | > | Inrush current : <30A peak @ 115VAC; <50A peak @ 230VAC cold start @25¢XC |
| ¡@ | > | Input current : 2.5A max. (RMS) @ 115VAC |
| ¡@ | > | Efficiency : 85% typical at full load |
¡@
Output
Features
| ¡@ | > | Maximum power : 100W convection cooled; 120W with 30CFM forced air |
| ¡@ | > | Hold-up time :16ms at 100 watt load and 115VAC nominal line |
| ¡@ | > | Short circuit protection : Auto recover type |
| ¡@ | > | Over load protection : Over load protected @ 105% to 120% above following maximum rating |
| ¡@ | > | Over voltage protection : Output 110% to 120% above following nominal output. Latching type. |
| ¡@ | ¡@ | AC Recycle. |
¡@
Safety Standards
| ¡@ | (PENDING) UL 60950 CSA C22.2-No.60950 TUV EN60950 CB IEC 60950 |
¡@
EMI Standards
| ¡@ | (PENDING) FCC Class B CISPR22 Class B EN 55022 Class B 61000-3-2 CE |
¡@
DC Output & Features
| ¡@ |
|
||||||||||||||||||||||||||||||||||||||||||||||||||
| ¡@ |
Note : 1. At 25¢XC including initial tolerance, line voltage, load currents and output voltages adjusted to |
||||||||||||||||||||||||||||||||||||||||||||||||||
| ¡@ | factory settings. | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ¡@ | 2. Peak¡Vto¡Vpeak with 20MHz bandwidth with a tantalum 10uF in parallel with a 0.1uF ceramic | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ¡@ | capacitor. | ||||||||||||||||||||||||||||||||||||||||||||||||||
¡@
Mechanical Specification
| ¡@ |
![]() |
¡@
Matching Connectors
| ¡@ | > | CON1 = AC INPUT MOLEX P/N: 09-65-2029 (OR EQUIVALENT) FEMALE HOUSING |
| ¡@ | ¡@ | MOLEX P/N: 09-76-1020 (OR EQUIVALENT) |
| ¡@ | > | CON2 = DC Output MOLEX P/N: 09-65-2068 (OR EQUIVALENT) FEMALE HOUSING |
| ¡@ | ¡@ | MOLEX P/N: 09-52-4064 (OR EQUIVALENT) |